Hardware Set Up
535 User's Manual Chapter 4 21
CHAPTER 4
HARDWARE SET UP
Hardware configuration determines the available outputs as well as the type of
input signal. The 535 controller comes factory set with the following:
All specified modules and options installed (for details, refer to the Order
Code in Chapter 1).
Process variable and remote setpoint set to accept a milliamp input.
Relay outputs set to normally open.
Altering the factory configuration of the 535, requires accessing the circuit
boards, and locating the jumpers and output modules (see Figure 4.1).
1. With the power off, loosen the four front screws, and remove them.
2. Slide chassis out of the case by pulling firmly on the bezel.
A detailed view of the circuit boards appears in Figure 4.2.
After configuring the hardware, or if no changes are necessary, continue set-
ting up the process as needed.
HARDWARE INPUT TYPES
The Process Variable
The 535 accepts several different types of process variable signals. Set a jumper
location to specify the type of input signal. Set the signal range in the software
(see Chapter 5 for software menus, or Chapter 7 for applications).
The jumpers for the process variable are located on the Microcontroller Circuit
Board (see Figure 4.2). The factory default is Milliamp. Locations are marked
as follows:
V Voltage
MA Milliamp
TC
Thermocouple with downscale burnout
TC
Thermocouple with upscale burnout
RTD RTD
NOTE: Thermocouple downscale
and upscale burnout offers a choice
in which direction the controller
would react in the event of
thermocouple failure. For example,
in heat applications, typically, it is
desirable to fail upscale (TC s) so
that the system does not apply more
heat.
NOTE: Hardware configuration of the
controller is available at the factory;
Consult a Moore Industries application
engineer for details.
Figure 4.1
Location of Printed Circuit Boards for
Hardware Configuration
MICROCONTROLLER
BOARD
POWER SUPPLY
BOARD
OPTION BOARD
FRONT FACE
Vista de página 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 143 144

Comentários a estes Manuais

Sem comentários

Dataram DTM64356A Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Speichermodule Dataram DTM64356A.
Wir stellen 1 PDF-Handbücher Dataram DTM64356A zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Datenblatt


Dataram DTM64356A Datenblatt (13 Seiten)


Marke: Dataram | Kategorie: Memory modules | Größe: 0.16 MB |

 

Inhaltsverzeichnis





Weitere Produkte und Handbücher für Speichermodule Dataram

Modelle Dokumententyp
DRH1066R/8GB Datenblatt   Dataram DRH1066R, 1 Seiten
GRH890I2/32GB Datenblatt   Dataram 16GB(2 x 8GB) DDR3, 1 Seiten
DRHZ600U/4GB Datenblatt   Dataram DRHZ600U/2GB memory module, 1 Seiten
GRSX2270Q/16GB Datenblatt   Dataram 16GB DDR3-1066, 1 Seiten
DRSX4470M2L/8GB Datenblatt   Dataram DRSX4470M2L/16GB memory module, 1 Seiten
DTM63389C Datenblatt   Dataram DTM63389C memory module, 12 Seiten
DRL1333R2L8/4GB Datenblatt   Dataram DRL1333R2L4/4GB memory module, 1 Seiten
DTM64309 Datenblatt   Dataram 4GB PC3-8500, 12 Seiten
DTM64305C Datenblatt   Dataram 2GB DDR3-1333, 11 Seiten
GRHXW9400D/8GB Datenblatt   Dataram 8GB DDR2-667, 1 Seiten
DRH8640/16GB Datenblatt   Dataram DRH8640/16GB memory module, 1 Seiten
GRI750/32GB Datenblatt   Dataram 16GB(2 x 8GB) DDR3-1066, 1 Seiten
DRL667FBQ/16GB Datenblatt   Dataram DRL667FB/8GB memory module, 1 Seiten
DTM64330A Datenblatt   Dataram DTM64330A memory module, 12 Seiten
GRL800U/8GB Datenblatt   Dataram 8GB(2 x 4GB) DDR2-800, 1 Seiten
DRH6600/8GB Datenblatt   Dataram DRH6600/32GB memory module, 1 Seiten
DRH980Q/16GB Datenblatt   Dataram 8GB DDR3-1333, 1 Seiten
GRSM3000/16GB Datenblatt   Dataram 16GB(4 x 4GB) DDR2-667, 1 Seiten
GRH1066RQ/16GB Datenblatt   Dataram GRH1066RQ/16GB memory module, 1 Seiten
DRH800R/8GB Datenblatt   Dataram 8GB(2 x 4GB) DDR2-800, 1 Seiten