28 ca6153 revA
3 - Ignition Controlled Locks: Control of door locks when the ignition is cycled
ON or OFF.
OFF - Door locks not activated by ignition.
Lock and Unlock - Doors lock when ignition is turned on and unlock when
ignition is turned off.
Lock Only - Doors lock when ignition is turned on.
Unlock Only - Doors unlock when ignition is turned off.
4 - Trunk Output Timing - Red/White Output: Controls the output timing/type
of the RED/WHITE output.
1 Second Pulse - 1 second pulse output.
10 Second - Continuous output for 10 seconds.
20 Seconds - Continuous output for 20 seconds.
Latched until IGN ON - Continuous output until the vehicle’s ignition is turned
ON.
Latched ON until Button Press - Continuous output until the activation button
is pressed again.
5 - Horn Output Timing: Control the minimum horn pulse time in milli seconds,
some vehicle will require a longer pulse to activate the factory horn.
16mS 10mS 30mS 40mS 50mS
6 - Real Panic: Controls the panic out when triggered from the transmitter.
ON - Randomized horn honks when panic is triggered.
OFF - Standard pattern horn honks when panic is triggered.
7 - AUX 1: Controls the VIOLET/BLACK AUX 1 output activation type and timing.
Push and Hold - Output is continuously active until transmitter button is
released.
Latched - Output stays active until button is pressed again.
Latched until IGN ON - Output stays active until the ignition is turned on.
Dome Light Output - Output used for illuminated entry and is not controlled
by the AUX 1 function of the transmitter.
Defrost Output Single Pulse - Single 1 second pulse after start
Defrost Output Latched 5 Minutes - 5 minute continuous output after
remote start.