Code Alarm CR3 Manual do Utilizador Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
Example: The control codes for the output relays in expander one are to be programmed. The
first relay will have an ON code of 789 and an OFF code of 321
ARU: ENTER PROGRAM CODE
YOU: # 1 8 ÝÝ
ARU: RELAY NUMBER 1.1 DTMF ON CODE IS EMPTY
YOU: 7 8 9 ÝÝ
ARU: RELAY NUMBER 1.1 DTMF ON CODE IS789
YOU: ÝÝ
ARU: RELAY NUMBER 1.1 DTMF OFF CODE IS EMPTY
YOU: 3 2 1 ÝÝ
ARU: RELAY NUMBER 1.1 DTMF OFF CODE IS321
YOU: ÝÝ
#X9ÝÝ : RELAY FORMAT
This will specify the type of relays being used for each expander. The relays will be an
-
nounced asX.1 to X.4. Each relay may be of a different format. (0=standard, 1=latched,
2=timed).
Example: Relay one in expander one is to be set as a timed relay.
ARU: ENTER PROGRAM CODE
YOU: # 1 9 ÝÝ
ARU: RELAY NUMBER 1.1 FORMAT IS ZERO
YOU: ÝÝ
ARU: RELAY NUMBER 1.1 FORMAT IS TWO
YOU: ÝÝ
B1225E BARNETT ENGINEERING LTD. PAGE 9
Vista de página 9
1 2 ... 5 6 7 8 9 10 11 12

Comentários a estes Manuais

Sem comentários